List of primary equipment still Needed for running at Fermilab

 

Full slow controls computer system infrastructure (LANL)

 

 

Liquid Helium for Quench Commissioning (UVA)

 

 

 

 

Microporous Teflon semi-rigid cable for long NMR lambda/2 connections, need at least silver quality (LANL)

...

6 Medium wall 4ft long vacuum hose with KF-25 connection:

View file
nameSQ-00056930-1.pdf
height150
(LANL)

 

Adapters, T-connectors, and blank offs for KF-16, 25, 40: (McMaster-Carr) (UVA)

 

Remote Control Gate Valve for regulating flow on the mechanical pump backing pump (probably VAT 642): VAT control valve (UVA)

 

Lakeshore Readouts for temperature measurements of fridge and target stick (Need at least 3 1 more for experiment): Lakeshore (Tokyo)

 

Large Foam Tub with slanted opening on one end for LN2 (https://www.foamdesign.com/) (UVA)

 

Six 27-pin Fischer connectors male and female with vacuum tight seal and bent housing (see target insert parts page) (UVA)

 

Need new cold cathode pressure gauge for high vac for magnet vacuum space (https://www.pfeiffer-vacuum.com/en/products/measurement-analysis/measurement/digiline/gauges/) (LANL)

 

All connector lines for slow controls, USB serial converter, lots of long serial cables, extra power cables, cables, RS-232 (LANL)and RS-485

 

Target loading paraphernalia, large and small forceps, crucible tongs, large and small tweezers, 150 mm Stainless Steel Flat; Serrated Clamp, funnels, cup-top-funnel, strainers, Styrofoam cups, wooden q-tips (UVA)

 

Shim control needs micro-controller compatible with LabView, and patched into Magnet VI (UVA/UNH)

 

Need more ND3 for target material for the experiment (UVA)

 

Parts for multiple Cold NMRs for testing and for experiment, cold boards, controllers, etc (LANL)

 

Backup NMR system, VME crate and Q-meter parts (LANL)

 

Piping and Swagelok for gas flow system (UVA)

 

Need safety pop-off valve for the fridge, this could be automated but non-auto mechanical valves are more reliable for safety (UVA)

 

Dedicated system for magnet level monitoring on coils (sticking with ITM10?), level monitor (sticking with mercury iTC?, could be iPS if use added cards) (LANL)

 

Dedicated Computer systems slow controls, also use FNAL LabView (LANL)

 

Chiller monitoring systems (pumps, microwave, flow wheel and temp sensors) (UVA)

 

Target Annealing System (UVA)