Special Shift on 2023-Apr-12
Currently, only Liquefier A is running and will be automatically switched to "Idle" mode.
If you see the pressure PT503A goes above 8psi, then call Kenichi/Ishara/Dustin
Special Shift on 2023-Apr-10
Currently, only Liquefier A is running. So basically, we wanted it to keep producing LHe.
If you see the following behaviors on Dewar pressure (PT503) and cold head temperatures (TI502,504,506,508,510), and make sure the LQ-A produces liquid (level should keep going up).
then contact Ishara/Kenichi/Dustin as soon as possible.
Use this dedicated page for this monitoring: https://e906-gat1.fnal.gov/data-summary/e1039/target-par-preset/target-shift-20230409.php
- The Liq pressure (PT503) changes by >0.5 psi.
- The Liq inflow (FC501I) shows a scattered plot and most of those are zeros.
- The Liq outflow (FCI) changes on average by > 5 SLM.
- The cold-head temperatures (TI50*) go below 4 K or above 5 K.
Note: TI506A has been showing larger values than 5K, so for that one let's use the upper limit as 7K; but the rest of cold-head temps. have to be in the range of 4K-5K. - https://e906-gat1.fnal.gov/data-summary/e1039/target-par-preset/target-shift-20230409.php
Special Shift on 2023-Apr-09
The purpose is to make sure that the Liquefiers A & B are producing liquid, avoiding blocking or avoiding higher Dewar pressure.
...
Shift Schedule
Date | 09 (Su) | 10 (Mo) | 11 (Tu) | 12 (Wed) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Time | 00-08 | 08-16 | 16-24 | 00-08 | 08-16 | 16-24 | 00-08 | 08-16 | 16-24 | 00-08 | 08-16 | 16-24 | ||||
Monitoring Person | Farooq | ??? | ??? | ??? | ??? | Kenichi | Zulkaida | Farooq | Eric | Liliet & Ernesto | Yoshiki | Eric | Jay??? | |||
On-Call Person | Kenichi | Kenichi | Kenichi | Ishara | Ishara | Ishara | Kenichi | Kenichi | Kenichi |
If the on-call person does not respond to phone call, try other ways (Discord, e-mail, WhatsApp) or Kenichi/Ishara/Dustin.
...