The Confluence production environment will undergo a migration from 8am-5pm ET on Saturday, May 25th. The Confluence environment will be available in read only mode. Changes to data in Confluence will not be possible until the migration is complete.
New Page: https://github.com/uva-spin
GitHub pages:
https://github.com/UVA-LabVIEW-Projects/LabVIEW-Projects
https://github.com/E1039-Collaboration/e1039-target-controls
LabView Vi's & associated information
Instrument | Hardware | Vi avail. | GitHub location(s) | Assignment | Test Status | Install in the target computer | |
---|---|---|---|---|---|---|---|
1 | Magnet flow control (THCD) | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control/subvi_main | Zulkaida | How about "*_forhere.vi". Final setup?? MKS 946 and MKS 670 are included? | ||
2 | Separator flow control (THCD) | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control | Zulkaida | |||
3 | Fridge flow monitor (THCD) | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control/subvi_main | Zulkaida | |||
4 | Fridge nose level probe | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control | Zulkaida | Is it AMI 1700? | ||
5 | Run valve | In-progress | Harsha | ||||
6 | Bypass valve | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control | Harsha | |||
7 | High Accuracy Signal Conditioner: MKS 670B | For pressure sensor (MKS 690A) | Step #2 | https://github.com/uva-spin/Temperature-Pressure-VIs/tree/main/MKS_670_VIs | Kenichi (& Zulkaida) | ||
8 | Vacuum System Controller: MKS 946 | For pressure sensor (MKS 722B) * 2 | Step #4 | https://github.com/uva-spin/Temperature-Pressure-VIs/tree/main/MKS_946_VIs | Kenichi (& Zulkaida) | ||
9 | DAQ for MCC E-TC for | Sensor type: Omega SA1 RTD | In-progress | Need to check the plan with Waqar | Waqar? (Kenichi) | ||
t.b.n. | DAQ for Thermocouple: MCC E-TC | Sensor: Omega Type T, at target cave | In-progress | https://github.com/UVA-LabVIEW-Projects/LabVIEW-Projects/tree/main/Delcaor%20(Complete) | Kenichi?, Reggie? | ||
10 | LakeShore218 (8 channels) | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/LakeShore218 | Reggie | Error on target computer: Missing VIs: SQL Execute.vi, ADO Connection Create.vi, ADO Connection Open.vi, ADO Connection Destroy.vi. | ||
11 | LakeShore218 (Target Insert) | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/LakeShore218 | Reggie | |||
12 | Target Lifter | In-progress | Vibodha | ||||
13 | Basic Microwave motor controller | In-progress | Vibodha | ||||
14 | EIP Frequency counter | In-progress | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Motor%20controller | Vibodha | |||
15 | He3 Readout | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control/subvi_main | Need someone | |||
16 | Pressure Monitor | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control/subvi_main | Need someone | |||
17 | Vac_Pressure_Monitor | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control/subvi_main | Need someone | |||
18 | Gpib | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Cryo-Control/subvi_main | Need someone | |||
19 | Magnet PS | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Magnet-PS-Control | Zulkaida | |||
20 | Shim PS | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Magnet-PS-Control | Zulkaida | |||
21 | Mercury iXX | yes | https://github.com/E1039-Collaboration/e1039-target-controls/tree/master/Magnet-PS-Control | Zulkaida | |||
22 | Maxigauge | yes | https://github.com/UVA-LabVIEW-Projects/LabVIEW-Projects/tree/main/Maxigauge%20VIs | Zulkaida | |||
23 | EV105-N (Electronic valve) | Fairchite TA6000-104 | no (one Vi) | Zulkaida | |||
24 | EV102-N (Electronic valve) | Asco 8222G 002LT | no (one Vi) | Zulkaida | |||
25 | TE107-N (Temp. Sensor) | OmegaSA1 RTD | no (one Vi) | Zulkaida | |||
26 | TE108-N (Temp. Sensor) | OmegaSA1 RTD | no (one Vi) | Zulkaida | |||
27 | PT106-N (Pressure Sensor) | DWIER 626-11-GH-P1-E4-S1 | no (one Vi) | Zulkaida | |||
28 | PT110-N (Pressure Sensor) | DWIER 626-11-GH-P1-E4-S1 | no (one Vi) | Zulkaida |
Steps of VI Availability (Tentative)
- A few simple VIs for readout and configuration. It is to confirm that the device can be controlled with LabVIEW.
- A complete set of VIs for readout and configuration. Each VI should perform one function of the device.
- VIs for user interface.
- VIs for continuous measurement.
- VIs for continuous logging.
- Note that an integrated user interface (like PDP) for all the devices that we use will be considered in a future. We could use DQMH or CML DQMH.
Updates
Date | Title | Presenter | File |
---|---|---|---|
| Update on LN2 Bos | Vibodha | SCMeetig_August25.pptx |
| Zulkaida |