List of equipment, utilities, staffing and services need from Fermilab for target running and setup:
Inside Cave:
8 plugs/extensions for 10A 110-120 VAC 60 Hz standard US
Safety setup: lights rope for ODH and Magnetic field
At least one single phase 220 V (with same specifications as below: this is a backup source)
Power source for actuator: not yet specified
Outside Cave:
500L liquid helium added to liquifier per month
20L liquid nitrogen for heat shield per day
3 He4-Gas K 2200psi (99.95%) bottles per week
Liquid nitrogen supply for material handling: 40L/week
Vent system for liquid nitrogen boil-off to go out of the cave
Deionized water (8 gallons + 1 gallon/week) for chillers used to cool the microwave generator
6 Clean power and conditioner/surge-protector for NMR all on one isolated circuit with same ground
15 plugs/extensions for 10A 110-120 VAC 60 Hz standard US outlets
Set of 3 phase 220 V for pump stack
At least two single phase 220 V for Magnet and Microwave Generator
- Power Req: 200-240 V 50/60 Hz (prefer 208 V)
- Power consumption max: 3.3 kVA
Needs for setting up internal network at FNAL for target slow controls, access through firewall
Staffing:
One technician with specialized training 2 hour every day or every-other day for target changing and loading as well as liquifier and cryogenic operations