List of primary equipment still Needed for running at Fermilab

 

(LANL) NMR coax small connection pieces for lambda/2 tuning, Quote is here:

 

(LANL) NMR coax cables at least 20ft long and enough cable to make 20 units with SMA connectors

 

(LANL) Remote Control Gate Valve for regulating flow on the mechanical pump backing pump (probably VAT 642): VAT control valve

 

(LANL) Lakeshore Readouts for temperature measurements of fridge and target stick (Need at least 3 for experiment): Lakeshore

 

(UVA) Large Foam Tub with slanted opening on one end for LN2 (https://www.foamdesign.com/)

 

(UVA) Six 27-pin Fischer connectors male and female with vacuum tight seal and bent housing (see target insert parts page)

 

(LANL) Need new cold cathode pressure gauge for high vac for magnet vacuum space (https://www.pfeiffer-vacuum.com/en/products/measurement-analysis/measurement/digiline/gauges/)

 

(LANL) All connector lines for slow controls, USB serial converter, lots of long serial cables, extra power cables, cables, RS-232

 

(LANL) Target loading paraphernalia, large and small forceps, crucible tongs, large and small tweezers, 150 mm Stainless Steel Flat; Serrated Clamp, funnels, cup-top-funnel, strainers, Styrofoam cups, wooden q-tips

 

(LANL) The pressure sensor (main manometer, MKS?) did not respond correctly, this needs fixing (not sure what the issue is, seemed to be controller) and a backup setup

 

(UNH) Shim control needs micro-controller compatible with LabView, and patched into Magnet VI (David at UNH is looking into this)

 

(LANL) Need more ND3 for experiment

 

(LANL) Parts for multiple Cold NMRs for testing and for experiment, cold boards, controllers, etc

 

(UVA) Backup NMR system VME crate and Q-meter parts

 

(LANL) Piping and Swagelok for gas flow system

 

(LANL) fridge back-fill automated control system (might need as backup annealing system)

 

(UVA) Need safety pop-off valve for the fridge, this could be automated but non-auto mechanical valves are more reliable for safety

 

(LANL) Dedicated system for magnet level monitoring on coils (sticking with ITM10?), level monitor (sticking with mercury iTC?, could be iPS if use added cards)

 

(FNAL) Transfer lines for initial magnet cooldown tests

 

(LANL) Dedicated Computer systems slow controls

 

(UVA) Chiller monitoring systems (pumps, microwave, flow wheel and temp sensors)

 

(UVA) Target Annealing System