You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 42 Next »

Overview

What do you need to know about the polarized target system?

 

The polarized target system consists of 5 major subsystems:
  1. The cryogenic Evaporation Fridge is designed to provide high cooling power at 1 K.
  2. The CPI EIO (Extended Interaction Oscillator) is a microwave generator used in DNP.
  3. The Oxford Superconducting Magnet is vertically pointing split pair magnet needed for DNP.
  4. The Target Material is a frozen solid material with the necessary characteristics for nucleon polarization.
  5. The NMR (Nuclear Magnetic Resonance) system is needed to measure the polarization of the sample. 

What is special about the Drell-Yan Target

This system has the longest (along the beam-line) target cell to date for an evaporation fridge, this requires a unique microwave distributing horn and three NMR coils per target cell to further reduce systematics in the polarization measurement.  This system was configured with the intention of having the greatest instantaneous luminosity of any previous evaporation system by having a beam intensity of 3X1012 protons/sec for 5 seconds while using a large pump system (14,000 m3/hour).  We are also running an experiment with both polarized protons and neutrons which share different sensitivity to the overall figure of merit of the Drell-Yan asymmetry.

 

 

Unknown macro: {div}

Target Details

Introduction to the Drell-Yan PT

Polarized Target Expert

Polarized Target Operator

[Target System Photos]

Target Logbook

Polarized Target Training

Polarized Target Summary
Anneal Summary
Target Operators
Target Troubleshooting

Target Training Information

Training for the Drell-Yan target operators will consist of the General Target Training Pack, followed by a practical course when the target is installed and running.

General Target Training Pack
Target Expert Duties
Target Operator Duties

Operational Procedures

PDP Restart Procedure
Cryo Screen Restart Procedure
Target Movement Procedure
New Baseline Procedure
Thermal Equilibrium Measurement Procedure
Prepare Frig for Polarization
Anneal Procedure (Experts only)
Running with No Helium for Optics (Experts only)
[Target Replacement Procedure] (Experts only)
Magnet Energization Procedure (Experts only)

General Target Documents

EIO Manual
http://www.jlab.org/~pzhu/report/Polarized_Proton_Target.pdf Introduction to the Target by P. Zhu